Quickseal® Aseptic Disconnector on C-Flex® 374 Tubing

64127

Technical Features

3/8 inch ID x 5/8 inch OD (0.375 inch x 0.625 inch, 9.53 mm x 15.88 mm); 12 inch Length w/Quickseal® at 6 inches

Materials

AL TPE

Please log in or register to ​view pricing, download product documentation and CAD models.

Technical Detail 3/8 inch ID x 5/8 inch OD (0.375 inch x 0.625 inch, 9.53 mm x 15.88 mm); 12 inch Length w/Quickseal® at 6 inches
Materials AL TPE
CAD Model Available No
Manufacturing Environment Classification ISO Class 7 / 10,000 / Grade C
Manufacturing Aids - Mold Release - Lubricant used Information Not Available
Colorant in Part No
Regrind Used to Manufacture This Part Information Not Available
Hazardous Goods No
Animal Derived Ingredients (BSE/TSE) Information Not Available
California Prop. 65 Information Not Available
Conflict Minerals Not known to contain tantalum, tin, tungsten or gold.
European Pharmacopoeia (EP) 3.1.X Information Not Available
Human Derived Ingredients Information Not Available
Latex Information Not Available
Latex in Packaging Information Not Available
Medicinal Substances Information Not Available
Nanomaterials Information Not Available
RoHS3 (2015/863) Information Not Available
Gamma Compatible Yes
Gamma Maximum Dosage (kGy) 50
Biocompatibility tested ISO 10993 No
USP Biocompatibility 87 Raw materials pass USP <87>
USP Biocompatibility 88 passes USP <88>, temperature not stated
USP Biocompatibility Claim Based On Raw Material
Residual Solvents: Tested via ICH Q3C Standard No ICH Q3C Testing Performed
Elemental Impurities: Tested via ICH Q3D Standard No ICH Q3D Testing Performed
Protein Absorption Data Available No
Extractables Testing Claims No Extractables Testing Performed
Visible-Subvisible Particulate Claim USP <788>
Bioburden USP 61 62 No bioburden information available
Tested via USP 661.1 No
Integrity Tested? No

The products in our inventory are intended solely for use as components for further manufacturing, processing or incorporation into a finished device. These products are not intended for use as finished devices. Customers are solely responsible for determining whether a Qosina component product is appropriate for customer’s intended use and for ensuring that the use of the component product is in compliance with applicable laws. Our components are not available for sale to hospitals, physicians, and pharmacists.

Need this part modified or a custom item?

By clicking 'Accept All' you consent that we may collect information about you for various purposes, including: Statistics and Marketing