TuFlux® SIL Tubing

T2300

Technical Features

60A Durometer; 1/8 inch ID x 1/4 inch OD (0.125 inch x 0.25 inch, 3.18 mm x 6.35 mm) x 328 ft coil (100 m)

Materials

Silicone

Please log in or register to ​view pricing, download product documentation and CAD models.

Technical Detail 60A Durometer; 1/8 inch ID x 1/4 inch OD (0.125 inch x 0.25 inch, 3.18 mm x 6.35 mm) x 328 ft coil (100 m)
Materials Silicone
CAD Model Available No
Packaging 328 ft coil (100 m)
Manufacturing Environment Classification ISO Class 7 / 10,000 / Grade C
Colorant in Part No
Regrind Used to Manufacture This Part Information Not Available
Hazardous Goods No
Product Shelf Life Non-Irradiation (months) 60
Product Shelf Life Post-Irradiation (months) 36
Animal Derived Ingredients (BSE/TSE) Conforms with EMA/410/01 rev. 3
California Prop. 65 Information Not Available
Conflict Minerals Not known to contain tantalum, tin, tungsten or gold.
European Pharmacopoeia (EP) 3.1.X Pass 3.1.9 Silicone
Human Derived Ingredients Information Not Available
Latex Information Not Available
Latex in Packaging Information Not Available
Medicinal Substances Information Not Available
Nanomaterials Information Not Available
Pyrogens Pyrogen free - Tested via USP <85>
REACH SVHC No Substance(s) Present Above Threshold
REACH SVHC Candidate List 2023 June 14 (235 Substances)
RoHS3 (2015/863) Information Not Available
Gamma Compatible Yes
Gamma Maximum Dosage (kGy) 50
Biocompatibility tested ISO 10993 Yes
ISO 10993-X Claim Based on Finished Component
USP Biocompatibility 87 Finished component passes USP<87>
USP Biocompatibility 88 passes USP <88>, temperature not stated
USP Biocompatibility Claim Based On Finished Component
Residual Solvents: Tested via ICH Q3C Standard No ICH Q3C Testing Performed
Elemental Impurities: Tested via ICH Q3D Standard No ICH Q3D Testing Performed
Protein Absorption Data Available No
Extractables Testing Claims Other Report
Visible-Subvisible Particulate Claim USP <788>
Bioburden USP 61 62 No bioburden information available
Tested via USP 661.1 No
Integrity Tested? No

The products in our inventory are intended solely for use as components for further manufacturing, processing or incorporation into a finished device. These products are not intended for use as finished devices. Customers are solely responsible for determining whether a Qosina component product is appropriate for customer’s intended use and for ensuring that the use of the component product is in compliance with applicable laws. Our components are not available for sale to hospitals, physicians, and pharmacists.